Successful treatment of coronary artery perforation during angioplasty using autologous vein graft-coated stent.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 9183598.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We report a case of successful treatment of coronary artery perforation and cardiac tamponade with an autologous vein graft-coated stent, which were developed during percutaneous transluminal coronary angioplasty. The method reported here may be an effective alternative to emergency surgery and should be considered when coronary artery perforation does not respond to conventional prolonged inflation with perfusion catheter.