A methodology for specifying PET VOI's using multimodality techniques.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 9262998.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Volume-of-interest (VOI) extraction for radionuclide and anatomical measurements requires correct identification and delineation of the anatomical feature being studied. We have developed a toolset for specifying three-dimensional (3-D) VOI's on a multislice positron emission tomography (PET) dataset. The software is particularly suited for specifying cerebral cortex VOI's which represent a particular gyrus or deep brain structure. A registered 3-D magnetic resonance image (MRI) dataset is used to provide high-resolution anatomical information, both as oblique two-dimensional (2-D) sections and as volume renderings of a segmented cortical surface. VOI's are specified indirectly in two dimensions by drawing a stack of 2-D regions on the MRI data. The regions are tiled together to form closed triangular mesh surface models, which are subsequently transformed into the observation space of the PET scanner. Quantification by this method allows calculation of radionuclide activity in the VOI's, as well as their statistical uncertainties and correlations. The methodology for this type of analysis and validation results are presented.
Medical subject headings
- Cerebral Cortex
- Image Processing, Computer-Assisted
- Tomography, Emission-Computed