Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?".
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 9314144.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To correlate the amount of radiation exposure to members of the orthopaedic surgical team based on their relative positions during a simulated fluoroscopically assisted orthopaedic procedure. Experimental study using commercially available fluoroscopic units and dosimetry badges designed to measure "eye" (ocular lens), "shallow" (hands/skin), and "deep" (whole-body) radiation exposure. Standard hospital operating room at a level one trauma center. Dosimetry badge clusters at specified distances from a fluoroscopic x-ray beam. Represented positions were direct beam contact, surgeon (12 in/30.5 cm), first assistant (24 in/70 cm), scrub nurse (36 in/91.4 cm), and anesthesiologist (60 in/152.4 cm). Dosimetry badges were systematically exposed by a protocol intended to maximize radiation scatter. A maximum time for continuous fluoroscope use was set at ten minutes. Radiation exposure readings from dosimetry badges processed by a commercially available dosimetry service. Maximum readings are reported. Direct beam contact resulted in approximately 4000 mrem/minute (40 mSv/min) of radiation exposure. Deep exposure for the surgeon and first assistant was 20 mrem/min (0.2 mSv/min) and 6 mrem/min (0.06 mSv/min), respectively. Superficial exposure was 29 mrem/min (0.29 mSv/min) for the surgeon and 10 mrem/min (0.1 mSv/min) for the first assistant. Eye exposure was 10 mrem/min (0.1 mSv/min) for the surgeon and 6 mrem/min (0.06 mSv/min) for the first assistant. At the scrub nurse position, no deep or eye exposure was detected. One positive badge for shallow exposure was noted at the scrub nurse position, reflecting a 2 mrem/min (0.02 mSv/min) exposure rate. After ten minutes of continuous exposure, badges assigned to the anesthesiologist position never registered any positive readings. These results indicate that unprotected individuals working twenty-four inches (70 cm) or less from a fluoroscopic beam receive significant amounts of radiation, whereas those working thirty-six inches (91.4 cm) or greater from the beam receive an extremely low amount of radiation.
Medical subject headings
- Air Pollution, Radioactive
- Film Dosimetry
- Fluoroscopy
- Occupational Exposure
- Operating Rooms
- Orthopedics
- Patient Care Team
- Personnel, Hospital