The cement mantle in the Exeter impaction allografting technique. A cause for concern.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 9355004.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The postoperative radiographs of 35 patients who underwent impaction allografting of the proximal femur were reviewed. Of Gruen zones that could be clearly visualized, 39.9% contained areas where cement was absent. Even when an adequate mantle was present, cement voids were commonly seen. These cement mantle deficiencies were confirmed in a series of cadaveric impaction allografting procedures. They appear to be a consequence, at least in part, of an inadequate differential between trial and actual component sizes. Additionally, 4 patients were identified with significant component migration secondary to radiographically visible cement mantle fractures within the first 6 months of surgery. It is concluded that the surgical technique requires modification to ensure a more consistent cement mantle and clinical result.