Increased sensitivity of HIV-1 antibody detection.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 9359701.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Clinical trial results from 11,344 paired urine and serum samples revealed 1,181 HIV-1-positive individuals confirmed by western blot (WB). There were 25 discrepant samples: 10 were urine enzyme immunoassay (EIA) and WB positive, serum non-reactive and serum WB negative or indeterminate, and 15 were serum EIA and WB positive, urine EIA non-reactive or urine WB negative or indeterminate. Serum samples, HIV-1 antibody WB confirmed, revealed a 99.15% sensitivity (1,171 out of 1,181); urine samples, HIV-1 antibody WB confirmed, showed a 98.73% sensitivity (1,166 out of 1,181). This study demonstrated that neither serum nor urine results alone are as sensitive for HIV-1 antibody detection as combined results of both samples.
Medical subject headings
- AIDS Serodiagnosis
- Blotting, Western
- HIV Antibodies
- HIV-1
- Immunoenzyme Techniques