To describe the management of condensation on the posterior surface of a foldable acrylic intraocular lens during vitrectomy and fluid-air exchange. A 70-year-old pseudophakic man with a foldable acrylic intraocular lens and open posterior capsule underwent vitrectomy and fluid-air exchange for repair of rhegmatogenous retinal detachment. During pars plana vitrectomy and fluid-air exchange, condensation immediately formed on the posterior surface of the foldable acrylic intraocular lens. This condensation, which prevented a view of the retina, was eliminated by wiping the posterior surface of the intraocular lens with a soft-tipped cannula. Although condensation may rapidly form on acrylic intraocular lenses during vitrectomy and fluid-air exchange, it can be managed readily by wiping with a soft-tipped cannula.
Medical subject headings
- Air
- Catheterization
- Fluorocarbons
- Humidity
- Lenses, Intraocular
- Methacrylates
- Postoperative Complications
- Vitrectomy