Cardiac pacemaker infection: surgical management with and without extracorporeal circulation.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 9436559.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Pacemaker infections are rare, but serious complications of pacemaker therapy. The generator pocket, the pacing leads, or both may be involved. We report on 12 patients with infected pacemaker systems. Four patients suffered from localized generator pocket infections, 6 had infected leads, and 2 patients had both. Pacemaker systems were completely removed in all patients. When the infection was limited to the generator pocket, the pacemaker system was removed at the original implantation site. Extracorporeal circulation was employed for the explantation of infected pacing leads. No complications occurred in patients with localized generator pocket infections. One patient with infected leads who was preoperatively already in a serious clinical condition died of septic shock in the early postoperative period; another patient died of pulmonary complications after tricuspid valve replacement 14 months after pacemaker explantation. No recurrent infections were observed. Explantation of the complete pacemaker system has proved a reliable method to eradicate infection. Complications have been rare, except in patients in a critically ill state who undergo cardiopulmonary bypass.
Medical subject headings
- Extracorporeal Circulation
- Pacemaker, Artificial
- Prosthesis-Related Infections