Psychological distress among recipients of Björk-Shiley convexo-concave valves: the impact of information.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 9470874.
- Also identified by PMC identifier 1892322.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To establish whether there is more psychological distress among recipients of Björk-Shiley convexo-concave (BScc) valves than among recipients of other valves not known to fracture. Cross sectional study. 137 patients who received either a BScc valve or a Sorin Biomedical spherical valve during a randomised trial between 1982 and 1983 at St Antonius Hospital, Nieuwegein. Systematic notification of the risk of strut fracture in recipients of BScc valves was carried out at St Antonius Hospital in 1991. Psychological distress as assessed with the General Severity Index from the Symptom Checklist 90. Psychological distress between recipients of BScc and Sorin valves did not differ irrespective of whether the recipients knew their valve type. More recipients of BScc valves, however, knew their valve type and of problems associated with artificial heart valves. Information about an increased risk of strut fracture does not induce psychological distress among well informed recipients of BScc valves. All recipients of heart valves should be systematically informed about their valve type--for example, by issuing data cards with valve serial numbers and other relevant information.
Medical subject headings
- Heart Valve Prosthesis
- Patient Education as Topic
- Prosthesis Failure