Side-to-side aorto-Gore-Tex central shunt.

Gates, R N; Laks, H; Johnson, K · Ann Thorac Surg · 1998

retrospective_cohort · Level III

Where this comes from

Abstract

This report details our experience in 13 patients with a technical modification of the standard central shunt. The study was performed using a retrospective chart review approach. In our operation, the aorto-Gore-Tex (W.L. Gore & Assoc, Flagstaff, AZ) anastomosis is created in a side-to-side fashion with the free end of the Gore-Tex shunt being oversewn. All patients had echocardiographic evidence of shunt patency in the immediate postoperative period, and there have been no cases of late shunt occlusion at a mean follow-up period of 10 months. We believe this approach will yield patency rates equivalent to or better than those of the standard central shunt. The technique has the advantage of creating a short, straight-lying shunt that is less likely to kink or be injured on repeated sternotomy and in which flow may be more reliable.

Medical subject headings