Pulmonary vein injury through repetitive clip friction: an unusual cause of hemothorax.

Sîrbu, H; Herse, B; Busch, T; Dalichau, H · Ann Thorac Surg · 1998

case_report · Level V

Where this comes from

Abstract

Massive hemothorax developed in a 58-year-old man 12 hours after a left pneumonectomy. The source of bleeding was a tear in the pulmonary vein stump caused by a titanium clip that had been used during mediastinal lymphadenectomy. Postoperatively, the clip progressively sawed through the vascular wall of the pulmonary vein due to friction during the cardiac cycle.