Results of 2-stage reimplantation for infected total knee arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 9493534.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Optimum treatment of the infected total knee arthroplasty has not been clearly established. To clarify the efficacy of two-stage reimplantation, experience with 66 infected total knee arthroplasties in 64 patients who had been treated with 2-stage reimplantation total knee arthroplasty between September 1980 and October 1993 was reviewed. Of these, 55 knees in 54 patients were available for follow-up examinations at an average of 61.9 months (range, 28-146 months). The initial diagnoses were rheumatoid arthritis (14 knees) and osteoarthritis (41 knees). Reimplantation was successful in 80.0% of knees with low-virulence organisms (coagulase-negative Staphylococcus, Streptococcus), 71.4% with polymicrobial organisms, and 66.7% with high-virulence organisms (methicillin-resistant Staphylococcus aureus). Reimplantation was successful in 82% of patients with osteoarthritis and in 54% of patients with rheumatoid arthritis (P = .024). The success rate was 92% if infection occurred after primary arthroplasty but only 41% if after multiple previous knee operations (arthroscopy, osteotomy, or revision total knee arthroplasty) (P < .001).
Medical subject headings
- Arthritis, Infectious
- Arthroplasty, Replacement, Knee
- Prosthesis-Related Infections
- Staphylococcal Infections
- Streptococcal Infections
Anatomy
- knee