Gamekeeper thumb: comparison of MR arthrography with conventional arthrography and MR imaging in cadavers.

Ahn, J M; Sartoris, D J; Kang, H S; Botte, M J; Trudell, D; Haghighi, P; Resnick, D · Radiology · 1998

biomechanical · Level V

Where this comes from

Abstract

To compare magnetic resonance (MR) arthrography with conventional arthrography and standard MR imaging in the evaluation of gamekeeper thumb. Eighteen cadaveric thumbs with (n = 12) or without (n = 6) experimental abduction stress were examined with conventional arthrography, standard MR imaging, and MR arthrography. Standard MR imaging and MR arthrography were performed with 0.2-T (low-field-strength) extremity-only and 1.5-T (high-field-strength) magnets. Results of blinded imaging analyses were correlated with pathologic findings. Paired MR images and MR arthrograms were rated with a three-point scale. Fourteen ulnar collateral ligaments were torn, including eight nondisplaced (57%) and six displaced (43%) tears. For the presence of tear, diagnostic accuracy of conventional arthrography, low-field-strength MR imaging, high-field-strength MR imaging, low-field-strength MR arthrography, and high-field-strength MR arthrography was 83%, 89%, 90%, 94%, and 100%, respectively. With regard to displacement of the torn ligament, diagnostic accuracy was 61%, 89%, 90%, 94%, and 100%, respectively. MR arthrograms were rated superior to standard MR images in 72% and 90% of specimens with low-field-strength and high-field-strength magnets, respectively. Of the tested methods, MR arthrography proved to be the most sensitive to the diagnosis of a torn ulnar collateral ligament of the first metacarpophalangeal joint and of displacement of the torn ligament.

Medical subject headings