Biomechanical properties of the central third patellar tendon graft: effect of rotation.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 9608458.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The results of this study suggest that the central third of the patellar tendon may be stronger than previously reported. The mean ultimate load of a 15-mm bone-patellar tendon-bone composite was 4389 N (+/- 709 N); of the 10-mm wide composites, 2977 N (+/- 516 N); and of the 7-mm composites, 2238 N (+/- 316 N). Twisting the graft 90 degrees increased the strength (P < 0.05). Further twisting to 180 degrees had no significant effect compared with twisting to 90 degrees. This study supports the practice of using smaller (10 mm) bone-patellar tendon-bone grafts to avoid the potential complications of patellar fracture and graft impingement in the notch, and suggests the value of rotating the graft prior to tibial fixation.
Medical subject headings
- Anterior Cruciate Ligament
- Tendons
Anatomy
- knee