Unstable femoral neck fractures in young adults: treatment with the AO 130-degree blade plate.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 9619457.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the clinical outcome of the treatment of unstable femoral neck fractures using the AO 130-degree blade plate. Between 1980 and 1994, thirty-four consecutive patients younger than age fifty years with an unstable intracapsular femoral neck fracture (Garden Types III-IV) were treated with internal fixation. University Hospital Gasthuisberg, Leuven, Belgium. The AO 130-degree blade plate with an antirotation, 6.5-millimeter, partially threaded cancellous lag screw was used. Nineteen (63.3 percent) patients had an excellent result, seven (23.3 percent) had a good result, three (10 percent) had a fair result, and one (3.3 percent) had a poor result. Delayed union was observed in one case, and avascular necrosis was observed in two cases. Two implants perforated the subchondral bone. Stable fixation with the AO 130-degree blade plate avoids damage to the adjacent blood supply to the femoral head and appears to guarantee a good final outcome of unstable intracapsular femoral neck fractures in young adults.
Medical subject headings
- Bone Plates
- Femoral Neck Fractures
- Fracture Fixation, Internal
- Joint Instability
Anatomy
- femur