Effect of pulse duration on wound healing using a CO2 laser.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 9628499.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The authors investigated wound healing of incisions in the buccal mucosa of a canine model created using a CO2 laser with a short pulse structure (60 micros, 100 micros, and 120 micros) rather than a conventional continuous wave structure in a shuttered mode. The tissue from 10 animals was evaluated histologically and with tensiometry acutely and at postoperative days 3, 7, and 14. A Bonferroni-Dunn corrected ANOVA analysis at a 95% significance level was used to compare the effect of pulse duration on histologic morphology and wound tensile strength. The data indicate that shorter laser pulse durations create less lateral thermal injury (P < .009) and wounds with greater tensile strength (P < .005), resulting in earlier wound healing. The results also show that heat, sufficient to damage tissue, was conducted to adjacent tissue during laser pulses of 100 micros and longer. These results demonstrate that surgical CO2 lasers with a short pulse structure of approximately 60 micros or less could offer more prompt wound healing while maintaining the advantages of a 10.6-microm wavelength laser.
Medical subject headings
- Carbon Dioxide
- Lasers
- Wound Healing