Arteriovenous fistula using transposed basilic vein.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 9635814.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Patients who need long-term haemodialysis often require multiple operations to maintain their vascular access. The options for secondary or tertiary access procedures may become increasingly limited. Prosthetic conduits are commonly used in difficult cases but are associated with a high incidence of complications. The brachial artery-transposed basilic vein arteriovenous fistula has been used in preference to a prosthetic graft on 31 occasions. There were no technical failures and 28 of these fistulas matured. No major infective complications occurred. This procedure should be considered before resorting to a prosthetic graft for vascular access.
Medical subject headings
- Arm
- Arteriovenous Shunt, Surgical
- Brachial Artery
- Catheters, Indwelling
- Renal Dialysis
- Veins