Real-time measurement of lysis of mural platelet deposits by fibrinolytic agents under arterial flow.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 9662163.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
An in vitro whole blood reperfusion model was employed to quantify: (a) initial rates of lysis of mural platelet deposits from flowing blood onto fibrin-coated surfaces and (b) plasmin-mediated consumption of plasma plasminogen and fibrinogen, by recombinant tissue-type plasminogen activator (rt-PA) and two t-PA variants, KHRR 296-299 AAAA (K-tPA) and T103N, N117Q, KHRR 296-299 AAAA (TNK-tPA), at wall shear rates of either 500 or 1000 s(-1). K- and TNK-tPA are more fibrin-specific than rt-PA, and are also resistant to inactivation by plasminogen activator inhibitor-1 (PAI-1). At 500 s(-1), no agent showed significant lysis of mural platelet deposits on fibrin, even at concentrations as high as 10 microg/ml of blood. At 1000 s(-1), each agent demonstrated a dose-dependent lysis of mural platelet deposits, due to plasmin-mediated lysis of the fibrin substrate (fibrinolysis). The local concentration of thrombolytic agents close to the fibrin-coated surface is probably higher than the concentration of released PAI-1 from the adherent and activated platelets. Hence, the initial rates of lysis achieved by K- and TNK-tPA were not significantly different from that by rt-PA, when each agent was tested at either 1 or 10 microg/ml of blood. However, TNK-tPA, at 1 microg/ml, caused the most extensive lysis at the end of the 50 min reperfusion period (50% vs 29% and 17% by rt-PA and K-tPA, respectively). K- and TNK-tPA, at concentrations as high as 10 microg/ml of blood, caused plasminogen activation that was controlled by the natural plasmin inhibitors, and, thus, no proteolytic degradation of plasma fibrinogen (fibrinogenolysis). On the contrary, rt-PA at 1 microg/ml revealed slight fibrinogenolysis that became extensive at 10 microg/ml. This study demonstrates the potential use of an in vitro model, that mimics the in vivo hemodynamic environment, in evaluating the performance of thrombolytic agents. The data suggest that: (a) adequate flow must accompany fibrinolysis for successful embolization, and (b) the TNK variant may lyse annular thrombi after recanalization, at least as efficiently as rt-PA does, while causing lesser defect of systemic hemostasis.
Medical subject headings
- Blood Platelets
- Fibrinolytic Agents