Muscle and musculocutaneous flap coverage of exposed spinal fusion devices.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 9703074.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Midline wound dehiscence in the back with exposure of spinal stabilization devices remains a challenging problem, mainly in the presence of infection. Usually, the treatment consists of instrumentation removal, wound debridement, and antibiotic therapy. These can result in instability of the spine and significantly prolong the hospitalization. The use of muscle and musculocutaneous flaps provides excellent soft-tissue coverage, obliterates the dead space, controls the infection, and creates conditions to salvage the hardware. Eight cases of spinal rod instrumentation, complicated by wound infection and dehiscence, have been treated successfully with single or multiple muscles and musculocutaneous flaps. Our method of treatment for these complex wounds, in two institutions, is discussed.
Medical subject headings
- Spinal Fusion
- Surgical Flaps
- Surgical Wound Dehiscence
- Surgical Wound Infection