Anodal block in F-wave studies.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 9749684.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine whether F-wave results differ with the anode proximal or distal to the cathode, ie, if clinical anodal block exists. Prospective study of 30 healthy volunteers undergoing nerve conduction and F-wave studies in one median nerve. A needle cathode electrode was used with a surface anode placed alternately proximal and distal to the cathode. The same electromyographer performed all studies with a Dantec Counterpoint machine. F-wave latencies were essentially unaffected by distal versus proximal positioning. Minimum, maximum, and mean F-wave latencies correlated extremely highly (r=.973 to .988). For both F-wave and M-response latencies and amplitudes, differences between mean values obtained using the two methods were extremely small and were neither clinically nor statistically significant. The frequency of elicitation of F-waves may (p < .05) have been slightly (3.5%) lower when the anode was in the distal position. Anodal block is not seen in F-wave studies when using needle electrode stimulations. Reversing the stimulator does not seem to be required. Further study with surface stimulating electrodes is underway to confirm results.
Medical subject headings
- Electrodes
- Electromyography
- Median Nerve
- Muscle, Skeletal
- Neural Conduction