Changes in arterial-mixed venous oxygen content difference (CaO2 - CvO2) and the effect on shunt calculations in critically ill patients.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 9771315.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Many commonly used indices of pulmonary oxygen transfer assume that CaO2 - CvO2 is constant. We studied changes in CaO2 - CvO2 in critically ill patients to determine the effect on calculated shunt of assuming a fixed CaO2 - CvO2. Two hundred pairs of arterial and mixed venous blood gas measurements were obtained retrospectively from 43 patients, each providing four or five pairs from a period of 48 h. CaO2 - CvO2 range from 13 to 74 ml l-1. The mean within-patient sd was 6.8 ml l-1 and the overall between-patient sd was 10.9 ml l-1. Our results show that assuming a fixed CaO2 - CvO2 leads to errors in quantifying pulmonary oxygen transfer.
Medical subject headings
- Critical Illness
- Oxygen
- Pulmonary Gas Exchange