Refined use of scintigraphy in the evaluation of nodular thyroid disease.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 9780985.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Scintigraphy has been advocated in patients with a thyroid nodule when fine needle aspiration biopsy (FNAB) is not definitive. The purpose of this study was to determine the incidence of hyperfunctioning nodules in patients without a definitive FNAB, the correlation of serum thyrotropin (TSH) levels with the functional status of a nodule, and whether a sensitive TSH assay can be used in lieu of scintigraphy. From 1990 to 1996, patients with a thyroid nodule were evaluated with FNAB and serum TSH measurement. Iodine-123 scintigraphy was reserved for patients without a definitive FNAB and was correlated with TSH levels. Of 356 patients with a thyroid nodule, 102 did not have a definitive FNAB. A hyperfunctioning nodule was diagnosed in 14 of the 102 patients. A low TSH level was detected in 12 (86%) of 14 patients with a hyperfunctioning nodule (mean = 0.04 +/- 0.38 microIU/mL) and only 20 (23%) of 88 patients with a hypofunctioning nodule (mean = 0.87 +/- 4.11 microIU/mL) (P < .05). Only 2 of 70 (2.8%) patients with a normal or increased TSH level had a hyperfunctioning nodule. A 14% incidence of hyperfunctioning nodules in patients without a definitive FNAB warrants the use of scintigraphy but only when serum TSH levels are low, thus avoiding unnecessary scans in 91% of patients with a thyroid nodule.
Medical subject headings
- Thyroid Nodule