Fatal cardiac tamponade associated with posterior spinal instrumentation. A case report.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 9802166.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Case report of a fatal complication of pedicle screw instrumentation and review of the literature. To describe the clinical and postmortem findings in a 35-year-old man who sustained a T11 burst fracture that was managed by transpedicular posterior instrumentation and who died 12 days after surgery of cardiac tamponade caused by a prick injury of the right coronary artery. Posterior pedicle screw instrumentation is considered a safe and effective method for stabilizing a spinal motion segment. Nevertheless, there are several rare but significant complications that may occur. This is the first report of a heart tamponade after transpedicular screw insertion. A 35-year-old man was treated for a T11 burst fracture with posterior transpedicular stabilization. The surgery was uncomplicated. Twelve days after the intervention, the patient died of cardiogenic shock. Postmortem examination showed a heart tamponade of 350 mL blood originating in a prick injury of the right coronary artery. Histologic findings showed evidence that the injury was caused during surgery by a Kirschner wire. There are numerous possible intraoperative complications in posterior pedicle screw fixation, such as nerve root and spinal cord injuries. This case of a fatal heart tamponade after transpedicular screw insertion is rare. It shows that the surgeon must be aware of potential risks associated with such a procedure and have a comprehensive three-dimensional understanding of the anatomic structures involved.
Medical subject headings
- Bone Screws
- Cardiac Tamponade
- Intraoperative Complications
- Spinal Fusion