Anion gap and hypoalbuminemia.

Figge, J; Jabor, A; Kazda, A; Fencl, V · Crit Care Med · 1998

cross_sectional · Level IV

Where this comes from

Abstract

To show how hypoalbuminemia lowers the anion gap, which can mask a significant gap acidosis; and to derive a correction factor for it. Observational study. Intensive care unit in a university-affiliated hospital. Nine normal subjects and 152 critically ill patients (265 measurements). None. Arterial blood samples analyzed for pH, PCO2, and concentrations of plasma electrolytes and proteins. Marked hypoalbuminemia was common among the critically ill patients: 49% of them had serum albumin concentration of <20 g/L. Each g/L decrease in serum albumin caused the observed anion gap to underestimate the total concentration of gap anions by 0.25 mEq/L (r2 = .94). The observed anion gap can be adjusted for the effect of abnormal serum albumin concentrations as follows: adjusted anion gap = observed anion gap + 0.25 x ([normal albumin] [observed albumin]), where albumin concentrations are in g/L; if given in g/dL, the factor is 2.5. This adjustment returns the anion gap to the familiar scale of values that apply when albumin concentration is normal.

Medical subject headings